View and Download Bewator BM3 installation & user manual online. BM3 Intercom System pdf manual download. View and Download Bewator BC615 installation and user manual online. BC615 Card Reader pdf manual download. You can examine Bewator K44 Duo Manuals and User Guides in PDF. View online or download 1 Manuals for Bewator K44 Duo. Installation & user manual.

  1. Installation Guide
  2. Th8320r1003 Installation Manual
  3. Th8320u1008 Installation Manual

Installation Guide

. Bewacard BC615, BC615Prox, BC615EM Installation and User manual. Copyright © 2004 Bewator AB, Solna, Sweden.

Material from this manual may only be copied with the consent in writing of Bewator. Bewator reserves the right to alter both the content of the manual and the design of the product. 16 Recommended cables.18 Considerations concerning earthing & screening.18 Connecting the power supplies.19 Connecting BC615 to the CR1 converter.21 ENTRO WIRING EXAMPLE.23 COMMISSIONING THE SYSTEM. 24 Standalone card readers.24 Card readers in Entro systems. BC615 Installation and User Manual) Cancel card (without card). 35 Program/change/erase common code.35 Program holidays.36 Delete individual holidays.36 Delete all holidays.37 Set door release time. 37 Set door held warning time.

Bewator Bm3 Installation Manual

37 Buzzer on/off.38 Calculated PIN. See also chapter Proximity function on page 12 for more information of the proximity function. BC615 can be used as a stand-alone unit or be included in a system consisting of several BC615 card readers. BC615 Installation and User Manual Features included These are the main features included in BC615:. Six different security levels.

Various methods of opening the door, e.g. Card, Card + PIN and Common code. Built-in time clock. Enables time control of cards and security levels. BC615 Installation and User Manual How does the card reader work? BC615 can easily be adapted to the security requirements in a particular building, a particular day of the week or time of day.

To make this possible you have to be familiar with the following concepts:. BC615 Installation and User Manual Examples of timing security levels During office hours, when there are people in the premises, the security level may not need to be so high: Unlocked door or Common code may be suitable levels.

Serial key antidote 8 v2. During lunch time, the level may be raised to Card. BC615 Installation and User Manual Time zones and day types There are two purposes of creating time zones:. To be able to assign different security levels to different times of the day. To be able to make certain cards valid at certain times. BC615 Installation and User Manual Each time zone may consist of two intervals.

To be able to assign suitable security levels to the office example above, the following time zones are needed: Time zone no Applies Applies 24 hours a day (all day types). Note: Default time zone that can be changed.

BC615 Installation and User Manual Time schedules There are two purposes for creating time schedules: To be able to combine time zones for the control of security levels. To be able to combine time zones defined for the time control of specific cards. BC615 Installation and User Manual Proximity function General The Proximity function means that the reader can read cards or tags without them being in contact with the reader.

The reader continuously transmits a low power radio frequency. When a card or tag is presented within the field of the reader it activates and transmits a unique identification number (card number) back to the reader.

BC615 Installation and User Manual Keypad layout Diagram of the LEDs and pushbuttons on the BC615 keypad. Indicates keypresses.

Lit when PIN code should be entered. Indicates errors. Cancellation of card following 3 incorrect PIN codes. To cater for disabled persons, a suitable height is approximately 95 cm. When installing the BC615-Prox, care should be taken to avoid sources of electrical noise, such as motors, generators, pumps, computer installation and mains cabling.

BC615 Installation and User Manual How to select connecting cables It is important to use cables with the correct conductor gauge, to keep the voltage drop in the cables as low as possible. 12 volt supplies. A 12 V electric locking device generally needs at least 11 V to work properly, so the voltage at the card reader should never be less than 11 V. BC615 Installation and User Manual Wiring LINK OUT DOOR CON 1 2 3 4 5 6 7 8 9 12-30V LOCK Connection to PC ALERT Wall 9 pin 25 pin RS-232 socket DSUB DSUB ENAB RS-232 ENAB BACK LIGHT.

The SW1 push button. Used when erasing the memory and setting a new password. If the card reader is part of a Bewator Entro system, place jumper on INT (attempts of tamper will be displayed as messages on the PC’s screen), otherwise to EXT. (Direct connection to external. BC615 Installation and User Manual Recommended cables Cable from Bewator Entro to CR1 Maximum length: 1200 metres. Pair twisted screened (1 pair + screen), e.g. Beldon 9502 (communication) and 1.5mm (power).

PAARFLEX CY (Bewapass custom cable comprising communication and power in one cable). BC615 Installation and User Manual Connecting the power supplies Connect the power supply according to the instructions below, but do not connect the power to outgoing cables. Apply power when you start the system (see the Check the communications circuit section). BC615 Installation and User Manual Central power supply If central power supply is used, precautions should taken against voltage drop. Dimension the power supply equipment and cables so that the voltage at the last door is not below the lock or reader’s tolerance. BC615 Installation and User Manual Connecting BC615 to the CR1 converter 12-24V 12-24V FRAME FRAME POWER 12-24V FG TX RX RTS 0V 12-24V LINK OUT DOOR CON 1 2 3 4 5 6 7 8 9 12-30V LOCK ALERT RS-232. BC615 Installation and User Manual Power LED.

Lit green when CR1 is powered. Yellow LED flashing quickly when CR1 is communicating with the PC. Flashes green/red when CR1 is communicating with the card reader. Power supply to card reader. Connect to terminal nos 1 and 2 on the BC615 circuit board. BC615 Installation and User Manual Entro wiring example In premises where the system is more extensive, the BC615 card readers can be connected to a Bewator Entro system.

SR32 BC615 BC615 BC615 BC615 BC615 BC615 BC615 BC615 Drop Drop Drop. Set the Link 1 jumper to N/W. Press SW1 for about 3 seconds.

The card reader starts beeping. Set the address (A1-A8 Entro) on the card reader keypad. Start programming Start programming according to the instructions in the Bewator Entro manual. BC615 Installation and User Manual Programming (standalone installation) In the sections below are the instructions on how to program the BC615 if the card reader is operating as a standalone unit. Programming Bewator Entro installations is described in the Bewator Entro manuals. BC615 Installation and User Manual Set password The first thing to do before starting to program the card reader is to set a password. Open the card reader with the key supplied.

The lock is located on the underside of the card reader. BC615 Installation and User Manual Set time and date Set the card reader to programming mode. Enter the current year, month and date, e.g.

981021 for the 21 October 1998. Enter the current day of the week. Example: 1 = Monday, 2 = Tuesday etc.

BC615 Installation and User Manual Program time zones This function is used to program the time zones to be used in the installation. Take out the completed time zone chart/s.

Set the card reader to programming mode. Enter the number of the time zone to be programmed. Use two digits, e.g. BC615 Installation and User Manual Program time schedules This function is used to program the time schedules to be used in the installation.

Take out the completed time schedule chart/s. Set the card reader to programming mode. Enter the number of the time schedule to be programmed. Use two digits, e.g. BC615 Installation and User Manual Define the “Door unlocked” security level Set the card reader to programming mode.

Fujitsu mini split installation manual

Enter the number of the time schedule to control the “Door unlocked” security level. Use two digits, e.g.

01 for time schedule Press B to leave programming mode. BC615 Installation and User Manual Define the “Card + PIN” security level Set the card reader to programming mode. Enter the number of the time schedule to control the “Card + PIN” security level. Use two digits, e.g. 01 for time schedule 1. Enter the time schedule during which the card/s should be valid. Use 2 digits, e.g.

01 for time schedule 1. Swipe the card (BC615) – or present the card (BC615-Prox). If several cards should be valid during the same time schedule, swipe or present these cards as well. BC615 Installation and User Manual Log on a card (without the card) Using this function, cards can be programmed by keying in the card number. Set the card reader to programming mode. Enter the time schedule during which the card/s should be valid.

Set the card reader to programming mode. Swipe the card (BC615) – or present the card (BC615-Prox). Swipe or present the next card, as required.

When finished, press B to go back to programming mode. BC615 Installation and User Manual Cancel card (without card) Using this function, cards can be cancelled using the card number. Set the card reader to programming mode. Enter the card number. If the card is not logged on the ”faulty programming”. BC615 Installation and User Manual Program holidays This function is used to pre-program holidays that do not occur on Sundays and holiday periods. Set the card reader to programming mode.

Enter the number of the holiday using two digits (01-15). BC615 Installation and User Manual Delete all holidays This function is used to delete all programmed holidays. Set the card reader to programming mode. Press A55 one more time. The unit automatically goes back to programming mode.

Set door release time The door release time determines for how long the lock should remain released following a correct transaction. BC615 Installation and User Manual Buzzer on/off The default is that the buzzer is activated. If you do not want the buzzer to beep on key presses or door opening, it can be turned off. Note that even when the buzzer is off for normal operation, it will continue to sound during programming. BC615 Installation and User Manual Calculated PIN If it is preferred not to have the users choose their own PIN codes, this function will enable automatic calculation of PIN codes, based on the card holder’s card number. Proceed as follows: Set the card reader to programming mode.

Bm3

Magnetic strip card reader When BC615 is delivered, the card reader reads positions 9 to 16 on the card’s magnetic strip, or the last 8 positions if they are fewer than 16. If you want to use your own cards and they should be read differently, enter from which position on the magnetic strip the reader should start reading and how many digits should be read (max. BC615 Installation and User Manual Change programming password To change the password: Press B and enter the present password. Enter the new password.

Th8320r1003 Installation Manual

A warning tone is heard. Enter the new password again. The warning tone sounds until all six digits have been entered. BC615 Installation and User Manual Erase the memory When the card reader’s memory is erased, the default settings are restored (see below). Set the card reader to programming mode. Open the card reader with the key supplied.

The lock is located on the underside of the card reader. BC615 Installation and User Manual Printout of events Using this function, printouts of events occurred can be requested. Set the card reader to programming mode. Press B to cancel the printout at any time. Printout format: YY-MM-DD D HH:MM TS XXXXXXXX TA. BC615 Installation and User Manual Printout of programmed time zones and time schedules Using this function, printouts of programmed time zones, time schedules and printer time zones can be requested.

Set the card reader to programming mode. Press B to cancel the printout at any time. BC615 Installation and User Manual Printout of reader information Set the card reader to programming mode. Press B to cancel the printout at any time. Printout format: BC615 Ver XX.XX Version number on software 04-02-27 5(5) 11:34 Date, Daytype, (Halfday) and Time.

BC615 Installation and User Manual Printout of logged on cards Set the card reader to programming mode. Press B to cancel the printout at any time. Printout format: XXXXXXXX TS Card number and Time schedule Press B to leave programming mode. BC615 Installation and User Manual Explanation on event codes Event code Explanation - Access events Access granted. Common code Access granted.

Card Access granted. Card + PIN Access granted. Card + PIN Duress Access denied. Illegal common code Access denied. Card not logged on Access denied. Choose/change PIN code (Calculated PIN not set) To choose/change your individual PIN (in Bewator Entro installations the PIN code is set from the PC): Press A on the card reader’s keypad. BC615 Installation and User Manual Duress This is how to activate the duress alarm output if forced to open the door under threat (this works during the Card + PIN security level only): Swipe or present the card at the card reader and enter the usual PIN code, only add 1 to the last digit in the code.

BC615 Installation and user manual Troubleshooting Problem Possible cause Action Red, yellow and green A button is pressed. Adjust the button. LEDs blink on power Memory error.

Th8320u1008 Installation Manual

Change card reader. Cannot enter Wrong password. Choose a new programming mode. Red LED external control: Galvanic insulation. Communications port: RS-232 (printer, PC or system). Temperature range: BC615: –35° C to +50° C BC615Prox & BC615EM: –30° C to +50° C (at 90% relative air humidity).

Housing protection class. BC615 Installation and user manual Charts Time zones Name interval interval (01-15) From From type/s Example: Name interval interval (01-15) From From type/s Working hrs 0830 1159 1300 1759 12345. BC615 Installation and User Manual Time schedules No (01-15) Name Time zones included Example: No (01-15) Name Time zones included Office staff 01020305 In the above example are time zones nos 1, 2, 3 and 5 included in time schedule no 1. BC615 Installation and user manual Security levels Level Time schedule Door unlocked Common code Card Card + PIN Toggle Special settings Function Setting Default Password 112233 Common code None Release time 7 sec Door held warning 10 sec time Buzzer.

BC615 Installation and User Manual Holidays No Date Duration No Date Duration (MMDD) in days type (MMDD) in days type Example: No Date Duration No Date Duration (MMDD) in days type (MMDD) in days type 1224 0701. BC615 Installation and user manual Persons Name Card number Time schedule Example: Name Card number Time schedule Edwards Anthony 12345678.